6 Step UK Marquee Earthing Checklist to Meet BS 7671 and BS 7909

6 Step UK Marquee Earthing Checklist to Meet BS 7671 and BS 7909

by rob | Sep 6, 2026 | Event Power Guides

For a temporary marquee in the UK, the safest arrangement is TN-S from a generator with a properly earthed star point, or a correctly designed TT system using driven earth electrodes. Never rely on a PME supply for a temporary outdoor structure. Whichever you choose,...
3% lighting, 5% circuits: Voltage drop calculation for UK events

3% lighting, 5% circuits: Voltage drop calculation for UK events

by rob | Sep 5, 2026 | Event Power Guides

Use VD = (mV/A/m × Ib × L) / 1000 to find the voltage drop in a circuit, then check it against BS 7671: 3% for lighting circuits and 5% for everything else, which correspond to voltage limits based on the supply voltage. Get the mV/A/m figure wrong, or forget the...
Ceeform Connectors: Specify 16–125 A and IP67 for Event Power

Ceeform Connectors: Specify 16–125 A and IP67 for Event Power

by rob | Sep 4, 2026 | Event Power Guides

Ceeform connectors are the industrial pin-and-sleeve plugs, sockets and couplers standardised under IEC 60309, covering rated voltages up to 1,000 V and currents up to 800 A. The name endures from entertainment and events wiring, but the specification you actually...
Facility Managers: 3 Alerts to Specify Remote Generator Monitoring

Facility Managers: 3 Alerts to Specify Remote Generator Monitoring

by rob | Sep 3, 2026 | Event Power Guides

Remote generator monitoring gives facility managers live visibility of run status, fuel, oil pressure and fault codes, with alerts sent the moment something drifts off spec. That means a flat battery or a failed start gets flagged before the next power cut, not after....
Prove Generator Output at 75%: Load Bank Testing for Maintenance Teams

Prove Generator Output at 75%: Load Bank Testing for Maintenance Teams

by rob | Sep 2, 2026 | Event Power Guides

Load bank testing proves whether a generator can actually deliver its rated kW under real load, and it burns off the carbon deposits that cause wet stacking. If your monthly exercise cycle never pushes past 30% of nameplate capacity, the fix is a stepped resistive...
40 Years of Event Power: Temporary Cabling Types UK Contractors Trust

40 Years of Event Power: Temporary Cabling Types UK Contractors Trust

by rob | Sep 1, 2026 | Event Power Guides

For most temporary supplies, H07RN‑F heavy‑duty rubber‑sheathed cable is the right choice outdoors, H05RN‑F or 300/500 V flexible cable covers indoor and low‑abuse runs, and LSZH‑rated cable is mandatory anywhere it routes through an escape route. SY cable turns up...
« Older Entries
Next Entries »

Recent Posts

  • Event Generator Sizing for UK Planners: Calculate 14 kW to 25–30 kVA
  • Build in 20–50% Headroom: UK Catering Power Calculation With BS 7909
  • UK Generator Earthing: 6 Site Proven Checks to Get Signed Off
  • Avoid Complaints: 3 Records UK Event Pros Must Log for Generator Noise
  • Save Up to 40% on UK Generator Running Costs With 40 Years’ Insight

Recent Comments

No comments to show.

Contact Details

P: 01273 063887

M: 07725 356419

E: [email protected]

Address

The Rotary, Morehouse Farm
Wivelsfield, East Sussex
RH17 7RE

Policies

Terms & Conditions
Privacy Policy

Info

Home
About
Services
Product Hire
Event Setup
Electrical Contracting
Marquees

Hire

Generators
Cables
Distribution
Adapters / Accessories
Lighting
Fuel

Website Design

×
1
Product selection
2
Contact information
3
Review information